Evaluation of indoor air pollutants in selected hostels of tertiary institutions in Owerri-Nigeria

dc.contributor.authorNnadozie, Chukwuemeka Fortunatus
dc.date.accessioned2026-05-30T13:26:49Z
dc.date.available2026-05-30T13:26:49Z
dc.date.issued2016-02
dc.descriptionThis thesis is for the award of Master of Science (MSc.) in Environmental Chemistry
dc.description.abstractThis study was aimed at evaluating the concentration levels of indoor air pollutants in some selected hostels located in four tertiary institutions in Imo state, Nigeria. It was conducted from February 2012 to July 2012. The pollutants such as: H2S, NO2, CH4, NH3, SO2, CO, Particulate matters and meteorological parameters; temperature, relative humidity, wind speed were measured. The gases were monitored using in-situ gas monitors while meteorological parameters were measured using multi-digital environmental meter. The observed concentration levels of indoor pollutants across the locations range as follows: H2S, 0.02 to 0.082ppm, NO2, 0.008 to 0.05ppm, CH4, 0.00 to 0.01ppm, NH3, 0.01 to 0.2ppm, SO2, 0.004 to 0.05ppm, CO, 0.6 to 9.25 ppm and particulate matters, 7.0 to 83Åg/m3 . The results revealed that the levels of pollutants were within the permissible limits of USEPA, WHO and FEPA. Multiple linear regression analysis of pollutants with meteorological parameters gave R- square (R2) values ranging between (0.490 to 0.618), implying that the studied meteorological parameters jointly influenced (49 to 62%) levels of the pollutants in the studied locations. The monthly means of the pollutants were analyzed using two way Analysis of variance (ANOVA), and some of the results showed probability levels at (p < 0.01 and p < 0.05). These generated indoor pollutants can build up to levels of public health concerns and have also been associated with a growing burden of diseases. It is therefore recommended that periodic monitoring of indoor pollutants; use of improved stoves and fuels, as well as improving ventilation systems could reliably protect the indoor environment and reduce human exposures
dc.identifier.citationNnadozie, C. F. (2016). Evaluation of indoor air pollutants in selected hostels of tertiary institutions in Owerri-Nigeria [Unpublished Master's Thesis]. Federal University of Technology Owerri, Nigeria
dc.identifier.urihttps://repository.futo.edu.ng/handle/20.500.14562/2785
dc.language.isoen
dc.publisherFederal University of Technology, Owerri
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectIndoor air pollutants
dc.subjectmeteorological parameters
dc.subjectDepartment of Chemistry
dc.subjecttertiary institutions
dc.subjectImo State
dc.subjectNigeria
dc.subjectparticulate matter
dc.titleEvaluation of indoor air pollutants in selected hostels of tertiary institutions in Owerri-Nigeria
dc.typeMaster’s Thesis

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nnadozie, C. F._Evaluation_2016.pdf
Size:
1.21 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.64 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections