dc.descriptionA resource article with figures and tables
dc.description.abstractRadiation levels were measured around eight diagnostic centres in Owerri, Imo State Nigeria using a portable Geiger Muller counter model GCA-04. The measurements were taken when the radiation sources (x-ray machines) were operational and non-operational. When the machines were non-operational, the background radiation ranged from 0.63 to 1.48 mSv/yr. When the machines were operational, the radiation levels ranged from 0.82 to 24.28 mSv/yr; this adds between 0.19 to 23.14 mSv/yr to the existing background radiation. The diagnostic centres used in this work have background radiation level below the world average dose limit of 2.16 mSv/yr for natural background radiation. Seven centres had annual dose rates that were below the 1.25mSv/yr dose limit for the public when the radiation source is not on and only one centre had a value still below the dose limit for the public when the radiation source was on. The other centres had higher values of annual dose rate when the safety of the general public is considered both for the cases when the radiation source was operational and non-operational.
dc.identifier.citationAmakom, M. C., Orji, E. C., Nkwoada, U. A., Nnonah, C. D. & Umunnakwe, C. M. (2018). Radiation levels around some X-ray diagnostic centres in Owerri, Imo State, Nigeria. International Journal of Recent Research and Applied Studies, 36 (1), 6 - 9
dc.identifier.urihttps://repository.futo.edu.ng/handle/20.500.14562/1799
dc.language.isoen
dc.publisherU. P.
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectX-ray
dc.subjectGeiger Muller counter
dc.subjectradiation
dc.subjectDiagnostic centres
dc.subjectOwerri
dc.subjectDepartment of Chemistry
dc.titleRadiation levels around some X-ray diagnostic centres in Owerri, Imo State, Nigeria
dc.typeArticle

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Amakom, C. M._Radiation_2018.pdf
Size:
226.84 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.64 KB
Format:
Item-specific license agreed to upon submission
Description: